Affected Software: Simcenter 11.0.0 and 11.0.1
Associated PR Number(s): 8343577
Scope: Windows 64-Bit & Linux 64-Bit
—————————————————————————-
PROBLEM:
Importing a load, constraint or simulation object which references an interpart expression can corrupt your model.
The “Import Simulation Entities” command is used to import simulation entities from a source simulation into the current simulation (i.e. import from source SIM model to current SIM model). Using this command to import a load, constraint or simulation object which references an interpart expression can corrupt your model.
Interpart expressions are expressions that are linked between part files. For example, an expression defined in a FEM can be linked and referenced in a related SIM as an interpart expression. If you use an interpart expression in the definition of a load and then copy it into a target simulation model via the “Import Simulation Entities” command, the target model can get corrupted.
This issue exists in Simcenter version 11.0.0 and 11.0.1.
REMEDY:
The issue does not exist prior to version 11, and the issue has been resolved in version 11.0.2 and following releases.